TENTESOL REFLEKTA

_

TENTESOL REFLEKTA

SIZE

TENTESOL EBAT1

TENTESOL-EBATLAR-2

TENTESOL-EBATLAR-3

Usage

Sisecam Tentesol, commercial buildings facade and / or windows, balconies ON THE glazing; The interior offers solutions for partition walls or decorative applications.

Advantages

Şişecam Tentesol, colorless or colored glass float line on the thin, reflective, mechanical and chemical resistance is obtained by applying a high pyrolytic hard coating.
Performance Tables
TENTESOL
Single Glazing

The above values ​​are given for univalent glass of 6 mm thickness.

“Daylight” and “Solar Energy” values, using spectral data measured in the laboratory according to EN 410 standard, “TNO Science and Industry” – is calculated at 3:01 WISE software package.

The value of the thermal conductivity coefficient was calculated according to standard EN 673 with WIS 3.01. Emissivity values ​​used in each calculation in a laboratory environment EN 673 (Appendix A) and measured according to EN 12898.

exposure to solar radiation throughout the surface of the glass piece, the temperature differences between day and night, because of factors such as heat absorption coefficients of the glass of the sexes may arise or chopping risk of thermal breakage. Depending on these factors require the use of tempered or partially tempered glass. This document does not have any calculation for thermal breakage risks. For questions regarding this matter please contact Sisecam Flat Glass.

This document is for informational purposes only and the information it contains without any warning Trakya Cam Sanayii A.Ş. It changed by.
In this document the differences between the actual value depending on the conditions of the place of use with a given value may occur. Because of these differences, Trakya Cam Sanayii A.Ş. not responsible in any way.

Daylight Permeability is the percentage of the light from the window glass.

Daylight Mirror (external): The percentage of incoming light reflected back by the window glass.

Total Solar Energy Transmission: The total percentage of incoming solar energy is coming on the glass. Lower total solar energy transmittance value, the better the solar control.

Shading Coefficient: Solar energy is compared to the total permeability of 3 mm colorless. The lower shading coefficient means better solar control.

Thermal Conductivity: the glass is a measure of thermal insulation. The lower the value, the better the thermal insulation, heating costs and less means more winter comfort. <

Insulating Glass

The values ​​above 6 mm Şişecam Tentesol outer glass + 16.12 mm + 6 mm in the intermediate space formed on the inner glass pane windows are for the layout.

“Daylight” and “Solar Energy” values, using spectral data measured in the laboratory according to EN 410 standard, “TNO Science and Industry” – is calculated at 3:01 WISE software package.

The value of the thermal conductivity coefficient was calculated according to standard EN 673 with WIS 3.01. emissivity values ​​used in the calculation of the value measured in vitro EN 673 (Appendix A) and EN 12898 “was measured according to.

exposure to solar radiation throughout the surface of the glass piece, the temperature differences between day and night, because of factors such as heat absorption coefficients of the glass of the sexes may arise or chopping risk of thermal breakage. Depending on these factors require the use of tempered or partially tempered glass. This document does not have any calculation for thermal breakage risks. For questions regarding this matter please contact Sisecam Flat Glass.

This document is for informational purposes only and the information it contains without any warning Trakya Cam Sanayii A.Ş. It changed by.

In this document the differences between the actual value depending on the conditions of the place of use with a given value may occur. Because of these differences, Trakya Cam Sanayii A.Ş. in no way be held responsible.

Daylight Permeability is the percentage of the light from the window glass.

Daylight Mirror (external): The percentage of incoming light reflected back by the window glass.

Total Solar Energy Transmission: The total percentage of incoming solar energy is coming on the glass. Lower total solar energy transmittance value, the better the solar control.

Shading Coefficient: Solar energy is compared to the total permeability of 3 mm colorless. The lower shading coefficient means better solar control.

Thermal Conductivity: the glass is a measure of thermal insulation. The lower the value, the better the thermal insulation, heating costs and less means more winter comfort.

Combination of Low-E Insulating Glass (Coating 3rd surface)

The value of the thermal conductivity coefficient was calculated according to standard EN 673 with WIS 3.01. emissivity values ​​used in the value of the account, under laboratory conditions EN 673 (Annex A) and EN 12898 ‘e Light ölçülmüştür.g as appropriate “and” Solar Energy “values, using the measured spectral data in the laboratory according to EN 410 standard,” TNO Science and Industry “- is calculated at 3:01 WIS software.

exposure to solar radiation throughout the surface of the glass piece, the temperature differences between day and night, because of factors such as heat absorption coefficients of the glass of the sexes may arise or chopping risk of thermal breakage. Depending on these factors require the use of tempered or partially tempered glass. This document does not have any calculation for thermal breakage risks. For questions regarding this matter please contact Sisecam Flat Glass.

This document is for informational purposes only and the information it contains without any warning Trakya Cam Sanayii A.Ş. It changed by.

In this document the differences between the actual value depending on the conditions of the place of use with a given value may occur. Because of these differences, Trakya Cam Sanayii A.Ş. in no way be held responsible.

Daylight Permeability
is the percentage of the light from the window glass.

Daylight Mirror (external): The percentage of incoming light reflected back by the window glass.

Total Solar Energy Transmission: The total percentage of incoming solar energy is coming on the glass. Lower total solar energy transmittance value, the better the solar control.

Shading Coefficient: Solar energy is compared to the total permeability of 3 mm colorless. The lower shading coefficient means better solar control.

Thermal Conductivity: the glass is a measure of thermal insulation. The lower the value, the better the thermal insulation, heating costs and less means more winter comfort.

Product description

Sisecam Tentesol, Sisecam Flat Glass is a solar control glass.

Şişecam Tentesol may also be contained in insulating glass systems, such as may be used in a single plate. Sisecam Low-E Glass Insulating Glass Systems created with the S Series, saves heating costs as well as the addition of solar control properties.

  • Building into the solar heat input limits, it monitors the sun’s extreme brightness, provides a comfortable working and living environment.
  • in air-conditioned environments by reducing cooling energy consumption, it saves on cooling costs.
  • When viewed from the direction in which light is strong creates a mirror effect. For example daylight hours inside out, contrary to the image provides one-way from outside to inside at night.
  • column with the aid of the reflective property in curtain sided building, beams, parapet walls, ceiling and provides image integrity hiding the structure elements such as installation spaces.
  • The coated surface inward (2.yüzey) is used in color facing, outward (1.yüzey) leads to the fore ‘is used in reflection of each other.
  • in stock thanks to the hard coating can be stored for a long time without damage.
  • Tempering, partial tempering, bending, laminating, and printing can be done on the enamel.

Note:

All solar control glass has a thermal breakage risks. Therefore, the use of tempered or partially tempered glass Şişecam Tentesol recommended. Laminated while tempering of all layers of laminated or toughened glass against thermal breakage risks must be.
Colors

Silver, green, gray, bronze and blue colors are available.

_

Get Information for Your New Project

Feel the difference of experienced team and corporate experience

Comments are disabled.

_